4.0 INSTALLATION INSTRUCTIONS
4.1 P
OLARITY
P
ROTECTION
(
AND
LED I
NDICATIONS
)
CAUTION: Although the ProStar is fully protected from
reversed polarity, the system operator and other
equipment may be at risk when polarities are
reversed. Carefully check each connection and
observe the LED’s to make sure polarity is correct.
CONNECTION POLARITY RESULT AND LED INDICATION
Battery Correct All 5 LED’s will sequence one time.
BATTERY TYPE
indicator will remain on
(default is sealed). The green
BATTERY
CHARGE
indicator will light within 15 sec-
onds, and will then cycle to the correct state.
Battery Reversed No LED’s will light. No damage will occur.
Sense Correct No additional indications.
Sense Reversed If the battery has been connected cor-
rectly, there will be sparking at the termi-
nals. If the negative sense lead is con-
nected first, no damage will occur (small
possibility of damage if positive connect-
ed first). There will be no indications.
PV Array Correct LED’s will light only if the battery has
been connected. During daytime with
battery present, the
CHARGING
indica-
tor will light after a 2 minute delay.
PV Array Reversed No damage will occur. The
CHARGING
indicator will not light after the 2 minute
delay.
Load N/A If a load short-circuit exists, load will
instantly disconnect to protect the
controller. LED’s will then sequence
to indicate a short.